WEST WIGHT POTTER 15 Bedienungshandbuch Seite 63

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 71
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 62
63
(2) There are glass-tube type fuses on the forward wall of the cabinet under the
stove. Refer to Figure 14-2. If you have a light or other electrical equipment
that doesn’t come on, then check these fuses to see if they are blown.
Figure 11-2
CAUTION: Do NOT install fuses bigger than 10 amps. A larger fuse will not
protect the wiring properly and could result in a fire.
(3) If you find one of the above fuses blown, then replace it with a 10 amp fuse.
If you continue to blow the fuse, you either have a short circuit or you have
connected too much additional equipment to the circuit. Take your boat to a
good electrical technician to find your problem. Bypassing the fuse or using a
larger fuse is likely to cause a fire.
(4) Optional equipment, like radios and depth-sounders, may have their own in-
line fuses. For the correct size fuse for these items, refer to the owner’s
manual for that piece of equipment.